ULTITEC 2000 Sleeve Gown
Premium Frontal Protection for Fluid Splash & Biological Hazards Resistant Sleeve Gown
With Type 5, Type 6, and EN 14126 certification, ULTITEC 2000 Sleeve Gown is designed to protect wearers against liquid splash and biological hazards from the operators’ front side.
The adjustable ties at the waist and neck are easy to fit the wearer’s body shape.
Features
An Effective Frontal Barrier Against Blood, Body Fluids and Infective Agents
The fabric performance exceeds both WHO protective clothing specifications Option 1 & 2 for Ebola Virus Disease Infection Control. [Note*]
Proven Frontal Protection of Fabric Performance Against Blood or Body Fluids
Meets Class 6 for ISO 16603 (Resistance to penetration by blood or fluids) under CE Standard EN 14126 (Against infective agents).
Proven Frontal Protection of Fabric Performance Against Blood-borne Pathogens
Meets Class 2 for ISO 16604 (Resistance to penetration by blood-borne pathogens) under CE Standard EN 14126 (Against infective agents)
Proven Frontal Protection of Fabric Performance Against Liquid Aerosol
Meets Class 3 for ISO/DIS 22611 (Resistance to liquid aerosol penetration) under CE Standard EN 14126 (Against infective agents).
Breathable to Work Efficiently
Designed for comfort use. Allow wearers to work efficiently while releasing their body heat to prevent heat exhaustion.
Passed ASTM F1670 Synthetic Blood Penetration Test for biohazard protection.
Note*: The WHO recommended specification for coveralls against filovirus disease issued in Oct, 2014 stated that healthcare workers should choose appropriate protective apparel, which meets the following two requirements:
option 1, tested for resistance to blood and body fluid penetration: meets or exceeds ISO 16603 class 3 exposure pressure.
option 2, tested for resistance to blood-borne pathogen penetration; meets or exceeds ISO 16604 class 2 exposure pressure.
Applications
Animal Disease Control ( African Swine Fever / Avian Influenza / Fall Armyworm ), H1N1 Influenza Management, COVID-19 Disease Control
Product Technology
Seam Construction
4-thread overlocked seam
- 7-9 stitched per inch
- Thread fibre is 150D
- Bite depth 4 mm
Fabric Construction
Microporous Film laminate PPSB
- MVTR is above 2500 gsm / 24hr (ASTM E96 BW)
- Hydro-head is above 2500 mm-H2O(EN 20811)
Back Fabric
Multilayer SMS fabric
Performance Chart
- Scroll the form to see more.
FABRIC PHYSICAL PROPERTIES | TEST METHOD | CLASS | |
---|---|---|---|
Abrasion Resistance | EN 530 | 1 | |
Flex Cracking Resistance | EN ISO 7854-B | 5 | |
Trapezoidal Tear Resistance | EN ISO 9073-4 | 1 | |
Tensile Strength | EN ISO 13934-1 | 1 | |
Puncture Resistance | EN 863 | 1 | |
Seam Strength | EN ISO 13935-2 | 3 | |
Antistaticity | EN 1149-5 | Pass | |
pH Value | EN ISO 3071 | Pass | |
Resistance to Ignition | EN 13274-4 | Pass | |
Resistance to Water Penetration | EN 20811 | >2500 mm H2O | |
Water Vapour Resistance [Ret] | EN ISO 11092 | 31.7 m²*Pa/W |
FABRIC CHEMICAL PROPERTIES | TEST METHOD | PENETRATION | REPELLENCY |
---|---|---|---|
Sulphuric acid 30% | EN ISO 6530 | Class 3 | Class 3 |
Sodium Hydroxide 10% | EN ISO 6530 | Class 3 | Class 3 |
o-Xylene | EN ISO 6530 | Class 2 | Class 1 |
Butan-1-ol | EN ISO 6530 | Class 3 | Class 2 |
Isopropanol* | EN ISO 6530 | 0.00% | 92.40% |
Note* Isopropanol test is not requested under EN 14325, therefore there is no classification
AGAINST INFECTIVE AGENTS with EN 14126 | TEST METHOD | CLASS | |
---|---|---|---|
Resistance to penetration by blood/fluids | ISO 16603 | 6 | |
Resistance to penetration by blood-borne pathogens | ISO 16604 | 2 | |
Resistance to wet microbial penetration | ISO 22610 | 6 | |
Resistance to liquid aerosol penetration | ISO/DIS 22611 | 3 | |
Resistance to dry microbial penetration | ISO 22612 | 3 |